Our site
The only location; no other cities are listed, and none are shown in the interface.
Kazan, Russia
A Tier III data center. The primary and only VDSVPS site.
Disks
NVMe on every plan. No hybrid or network-attached disks in the plans.
Network
A public IPv4, a 500 Mbit/s port, up to four extra addresses per machine.
Virtualization
KVM: every machine runs its own kernel; resources are not smeared across containers.
What Tier III means
Tier is the Uptime Institute classification of data centers. It does not describe “quality” in general but one specific thing: what happens to your server when the facility needs maintenance or something fails.
The defining property of Tier III is being concurrently maintainable. Any piece of the engineering infrastructure — a UPS, a cooling unit, a cable route — can be serviced or replaced without powering down the racks. At Tier I and Tier II that is impossible: planned maintenance there means downtime.
How the tiers differ
The availability figures are calculated values from the Uptime Institute methodology, not a promise from us. Real availability also depends on the hardware and on what the client does inside the machine.
| Tier | Redundancy | Maintenance without downtime | Expected availability |
|---|---|---|---|
| Tier I | None: a single power and cooling path | No — any work means downtime | 99.671% |
| Tier II | Partial: redundant equipment, single path | No | 99.741% |
| Tier IIIour tier | Multiple power paths, one active; N+1 redundancy | Yes: any component can be taken out for service | 99.982% |
| Tier IV | Two active paths, every component fault tolerant | Yes, and it survives a single failure | 99.995% |
In hours of downtime per year the gap between Tier II and Tier III is roughly 22 hours against one and a half.
What the tier is built from
Four engineering systems by which a data center is judged.
- Power: two independent feeds, diesel generators and uninterruptible supplies with N+1 redundancy, so servicing one of them does not darken the room.
- Cooling: chillers and air handlers with capacity to spare; a failure or a repair does not raise the temperature in the racks.
- Connectivity: several independent carriers and physically separate cable entries into the building.
- Physical security: guards, access control to the halls, video surveillance and visitor logs.
What of this our hall actually has
The machines sit in a Kazan data center that meets the Uptime Tier III requirements. Power and cooling are backed up on an N+1 scheme, the halls are kept at around 22 °C and about 40 % humidity, and site access and technical support run 24×7×365.
We do not publish the operator of the site, the layout of its power feeds or the list of uplinks: where the equipment stands is not disclosed. Data centers themselves write the same way — their descriptions carry the tier, the redundancy and the operating hours, but neither a floor plan nor a list of carriers.
All of the above is about the standard and the hall, not about one machine. The availability of your server also depends on what runs on it: no hall will save you from a full disk or a crashed application.
Why there is only one location
A list of ten cities looks more impressive than one, but selling a location that does not exist is a promise that breaks with the first order. While there is one site, the interface and the calculator show one city. When a second appears, it will appear in the list.
A machine in a Tier III hall
One site, NVMe on every plan and KVM with its own kernel for every machine. The trial lasts three days, except on VDS Pro.