Infrastructure

Data centers and locations

We have one site: Kazan. This page explains what the words “Tier III” stand for and what that level changes in day-to-day operation.

Tier III
data center level
1
site — Kazan
500 Mbit/s
port per machine
KVM
every machine runs its own kernel
01

Our site

The only location; no other cities are listed, and none are shown in the interface.

Kazan, Russia

A Tier III data center. The primary and only VDSVPS site.

Disks

NVMe on every plan. No hybrid or network-attached disks in the plans.

Network

A public IPv4, a 500 Mbit/s port, up to four extra addresses per machine.

Virtualization

KVM: every machine runs its own kernel; resources are not smeared across containers.

02

What Tier III means

Tier is the Uptime Institute classification of data centers. It does not describe “quality” in general but one specific thing: what happens to your server when the facility needs maintenance or something fails.

The defining property of Tier III is being concurrently maintainable. Any piece of the engineering infrastructure — a UPS, a cooling unit, a cable route — can be serviced or replaced without powering down the racks. At Tier I and Tier II that is impossible: planned maintenance there means downtime.

03

How the tiers differ

The availability figures are calculated values from the Uptime Institute methodology, not a promise from us. Real availability also depends on the hardware and on what the client does inside the machine.

TierRedundancyMaintenance without downtimeExpected availability
Tier INone: a single power and cooling pathNo — any work means downtime99.671%
Tier IIPartial: redundant equipment, single pathNo99.741%
Tier IIIour tierMultiple power paths, one active; N+1 redundancyYes: any component can be taken out for service99.982%
Tier IVTwo active paths, every component fault tolerantYes, and it survives a single failure99.995%
note

In hours of downtime per year the gap between Tier II and Tier III is roughly 22 hours against one and a half.

04

What the tier is built from

Four engineering systems by which a data center is judged.

  • Power: two independent feeds, diesel generators and uninterruptible supplies with N+1 redundancy, so servicing one of them does not darken the room.
  • Cooling: chillers and air handlers with capacity to spare; a failure or a repair does not raise the temperature in the racks.
  • Connectivity: several independent carriers and physically separate cable entries into the building.
  • Physical security: guards, access control to the halls, video surveillance and visitor logs.
05

What of this our hall actually has

The machines sit in a Kazan data center that meets the Uptime Tier III requirements. Power and cooling are backed up on an N+1 scheme, the halls are kept at around 22 °C and about 40 % humidity, and site access and technical support run 24×7×365.

We do not publish the operator of the site, the layout of its power feeds or the list of uplinks: where the equipment stands is not disclosed. Data centers themselves write the same way — their descriptions carry the tier, the redundancy and the operating hours, but neither a floor plan nor a list of carriers.

All of the above is about the standard and the hall, not about one machine. The availability of your server also depends on what runs on it: no hall will save you from a full disk or a crashed application.

06

Why there is only one location

A list of ten cities looks more impressive than one, but selling a location that does not exist is a promise that breaks with the first order. While there is one site, the interface and the calculator show one city. When a second appears, it will appear in the list.

A machine in a Tier III hall

One site, NVMe on every plan and KVM with its own kernel for every machine. The trial lasts three days, except on VDS Pro.